NovaStar Program Reference / Data Collection / sendrpt
Overview
The sendrpt
program files data reports.
Command Line Usage
The command line syntax is:
sendrpt [options] ID[/r#] DATA [D_T]
Command line parameters are:
Parameter | Description | Default |
---|---|---|
ID |
File data report for the remote or point ID or tag | |
ID/r# |
File rating data for the remote or point ID or tag | |
DATA |
File this data report value | |
D-T |
File this data report date and timeMM/DD/YYYY-HH:MM:SS YYYY/MM/DD-HH:MM:SS wher / can be [/+-., ] - or : are any non digit |
Current date and time |
-a |
Disable alarm checking | |
-c |
Send calibrated data | |
-C |
Force calibration of floating point data | |
-d [#] |
Increase or set the diagnostic display level | |
-f |
Force replacing reports already in database | |
-i |
Read reports from standard input | |
-l # |
Log file: 0 = nssyslog 1 = nsrecdata.log 2 = nsautointer.log |
0 |
-Oflags |
Data report flags: A = data report alarmed B = data series break E = data report verified M = maintenance data report O = data report rating over the rating table limit Q = data report questioned U = data report rating under the rating table limit V = data report valid |
|
-q |
Quiet - no messages | |
-R #secs |
Interval that prevents filing of repeat rports | |
-S # |
Source number for report flag | none |
-s #[smhd] |
Add time offset to report time | 0 |
-te D-T |
Stopping time for data filing | Current date and time |
-ts D-T |
Starting time for data filing | 01/01/1980 |
Examples
sendrpt -C 100 1.23 2016/12/25-01:02:03
This will file a data report for point ID 100 with a data value of 1.23, with forced calibration of floating point data. The report is filed in the novastar database table data_2016_12.
Scheduling
Explain whether run on a schedule...
NovaStar Administrator Interface
Explain how to access, including screen shots...
Troubleshooting
Explain, including log file name/location...